10 RECOMMENDED HIGH VOLTAGE DIELECTRIC WITHSTAND TESTING (Hi-Pot Testing)
Testing agencies such as UL, CSA, etc., usually require that equipment undergo a hi-pot test. In order to prevent
catastrophic damage to the control, which has been installed in the equipment, it is recommended that the follow-
ing procedure be followed. A typical hi-pot test setup is shown in Figure 13 on page 23. Note: All controls have
been factory hi-pot tested in accordance with UL requirements.
WARNING! When performing the hi-pot test, disconnect the AC power.
22
90 - 130 Volt DC Motors
(HP)
180 Volt DC Motors
(HP)
Plug-In Horsepower Resistor®
Value (Ohms) Part No.
1/100 – 1/50 1/50 – 1/25 1 9833
1/50 – 1/30 1/25 – 1/15 .51 9834
1/30 – 1/20 1/15 – 1/10 .35 9835
1/20 – 1/12 1/10 – 1/6 .25 9836
1/12 – 1/8 1/6 – 1/4 .18 9837
1/8 – 1/5 1/4 – 1/3 .1 9838
1/4 1/2 .05 9839
1/3 3/4 .035 9840
1/2 1 .025 9841
3/4 1
1
⁄2 .015 9842
1* 2* .01 9843
1
1
⁄2* 3* .006 9850
* Indicates an Auxiliary Heat Sink (Part No. 9861, or equivalent) must be used to achieve rating indicated.
TABLE 6 – PLUG-IN HORSEPOWER RESISTOR® SELECTION